How to Know If HVAC Zone Damper Is Bad?

A faulty zone damper can seriously affect your home’s comfort level. That’s why it’s incredibly important to be able to identify the problem as soon as possible. 

If you’re experiencing abnormal temperatures around the house, the HVAC system can’t maintain a stable temperature, and/or there is limited airflow, then a faulty zone damper might be to blame. Check the damper connections with a multimeter, if the reading is not around 24V, then the element is bad.

How to Know If HVAC Zone Damper Is Bad?

A tell-tale sign of a bad zone damper is the inability to keep each zone at a comfortable temperature. If there is something wrong with the element, the HVAC system won’t be able to correctly cool or heat the chosen zones.

How Do I Know If My Damper Motor Is Bad?

It is relatively easy to determine a bad damper motor without even having to look at the actual damper. Look out for the following signs:

  • Inconsistent and abnormal temperatures throughout the house
  • Inability to maintain a stable temperature in a certain zone
  • Limited airflow in the room

Read: Why HVAC Zone Damper Not Working? Troubleshooting Guide

How Do I Check My Dampers?

  1. Determine whether you have automatic or manual dampers. The latter will have a lever.
  2. Follow the ductwork from each damper to find out what area every component is responsible for.
  3. Turn the HVAC unit on (if you have a manual damper, open it using the lever). Check the airflow at the registers.
  4. If there is no or little air coming out of the registers when the dampers are supposed to be open, then the chances are high that the elements have gone bad.

Before testing the dampers, make sure that the air filters are clean and that there are no disconnected segments in the ductwork as these things can affect the airflow as well. 

How Do You Test a Zone Damper Motor?

There are quite a few different types of dampers, but a lot of them would either open or close once power gets applied to them. As soon as the elements stop receiving power – a spring would return the damper into its normal position (which can be either open or close).

Attempt testing the zone damper motor only if you feel comfortable working with electricity.

You would have to get a multimeter that reads AC volts. You can check the damper connections directly or the connections on the part of the zoning board that is responsible for the damper (usually labeled ‘zone 1 damper’ or something like that).

The reading should be roughly 24V. For some dampers, you would see these numbers while the damper is closed, and for others – while the element is open. 

Read: Honeywell Humidifier Damper Position On Winter/Summer

How Do You Reset a Zone Damper?

You can’t really reset a zone damper, but you can control when the damper should be open or closed. 

Have a Question? Ask HVAC Technician

Click here to use the chatbox to speak with one of our technicians.
No in-home service calls. No appointments.

Typically, you’d be able to do that with the help of the thermostat that is responsible for the zone you are troubleshooting. Simply set the thermostat to a higher or lower set point

How Do I Fix My HVAC Damper?

  1. Start by checking the thermostat setting and the zone control panel – in a lot of cases, these elements might be to blame.
  2. If the thermostats and the zone control panel are working properly, then you might have to remove the damper from the duct.
  3. Inspect the element for rust and accumulated dirt. Also, make sure that the wiring is not damaged.
  4. If you have only recently installed the dampers, then the components might have been poorly fitted – this can cause the damper to get stuck.
  5. If you have a manual damper, make sure that the lever was mounted correctly.

Read: What Are 4 Basic Categories Of HVAC Systems?

How to Troubleshoot Damper Actuator

  1. Turn the power to the system off.
  2. Locate the damper for the zone that you are experiencing issues with and disconnect the motor from the damper arm. While doing that, make sure to not bend anything.
  3. If the damper is closed and you can manually get it open, then the issue is most likely with the zone damper actuator.

Read: What Are Zoned HVAC Systems?

What Does Zone Damper Fault Mean?

If your HVAC equipment is showing ‘zone damper fault’, then it usually means that one of the zones in the system is not working.

In the majority of cases, this will happen if the damper is unresponsive. The damper won’t be able to respond to the thermostat’s commands if:

  • There is a loose wire
  • The damper motor had gone bad
  • There is a physical restriction to damper movement

Read: Why HVAC Not Working?

FAQs

How Long Do Zone Dampers Last?

With proper maintenance, you can expect your HVAC dampers to last for around 20 years. The main factors that are going to affect the elements’ lifespan include how frequently you run the unit, the quality of the equipment, and whether or not you follow a regular maintenance schedule. 

How Much Does a Zone Damper Cost?

The actual dampers can cost anywhere between $50 and $340. Automatic dampers would be a lot more expensive than manual dampers and the professional installation of these elements is going to cost more as well.

If you’re an experienced DIYer, it might be fairly easy for you to install a new manual damper. Do bear in mind, however, that it is generally recommended to leave the installation of automatic dampers to the professionals.

What Is the Major Cause of Thermostat and Zoning Failure?

The most common issues in zoning systems include:

  • Problems with the thermostats – wrong settings and issues with the wiring are a lot more common in multi-zone systems simply because there are more thermostats used.
  • Damaged dampers – dampers are the elements that turn an ordinary HVAC system into a multi-zone system. These components that control the airflow can become stuck or simply stop functioning due to a bad motor.

Do Dampers Damage HVAC?

Once the air that is getting pushed through the HVAC system hits the closed damper, it will increase pressure inside the ductwork which can potentially lead to problems with the equipment.

The good news is that such a situation cannot happen in a multi-stage HVAC system that has properly installed dampers. The blower does not always work at 100% capacity, so the air resistance inside the ductwork will not be too high.

How Do You Open a Damper Manually?

Manual dampers can be easily opened or closed with the help of a lever. If you have an automatic damper, you would have to disconnect the element from the damper motor to manually open it.

How Do You Open a Stuck Damper?

If the damper is accessible, inspect the element – you might notice dirt accumulation or a physical obstruction that’s preventing the damper from opening.

Improper installation or poorly fitted dampers might also be to blame. In such a case, the only thing that you can really do is get new dampers or call an expert to reinstall the element.

How Do I Know If My Damper Is Open?

If you can feel air coming from the registers, then the damper that is responsible for this zone is open. 

How Do You Troubleshoot a Vent Damper?

  1. Confirm that the damper is wired correctly.
  2. If wiring is not the issue, then disconnect the wires

Set your multimeter to AC and check the voltage across the wires (24 volts AC should be present).